To change the runner blocks, please proceed as follows:
  1. Disconnect the electrical and pneumatic supply of the entire conveyor system and secure against reconnection.
  2. Remove the mounting bolts of the two-corner element and remove it completely upwards.

    2 way Diverter Changing runner blocks Step2.1

    2 way Diverter Changing runner blocks Step2.2

  3. Loosen and remove the four mounting bolts of the runner block (right / left) to the angle bracket.
  4. Slide the runner block to be changed manually, to the end of the guide rail.

    2 way Diverter Changing runner blocks Step4

  5. Use the plastic runner block supports to avoid losing balls out of them while taking them off the rail.

    2 way Diverter Changing runner blocks Step5.1

    2 way Diverter Changing runner blocks Step5.2

    2 way Diverter Changing runner blocks Step5.3

  6. Put the runner blocks on the guide rails in reverse order.
  7. Install the entire two-corner element.
  8. Move the two-corner element into its end positions to check for possible mechanical blockages.
  9. Connect the electrical connections and check the function of the entire unit.
 
The guide rail must be cleaned before the installation of the new runner blocks. Check manually the freedom of movement of the runner blocks.