To tension the chain, please proceed as follows:
  1. Disconnect the electrical and pneumatic supply of the entire conveyor system and secure against reconnection.
  2. Loosen the four mounting clamps of the motor base plate.
  3. Move the entire unit against the running direction until the required chain tension is reached.
  4. Tighten the four mounting clamps.
  5. Connect the electrical supply.
  6. Check the function of the entire Lift & Rotate Unit.
  7. Please follow the steps in reverse order to re-install the indexing plate.

    Lift Rotate Tension chain 1

    Lift Rotate Tension chain 2