To remove the indexing plate, please proceed as follows:
  1. Disconnect the electrical and pneumatic supply of the entire conveyor system and secure against reconnection.
  2. Remove the two mounting bolts of the cylinder rod attachment bracket. (In case of two cylinders, both brackets have to be removed.)
  3. Release the four tab washers of the four guide shaft attachment bolts (with suitable tools).
  4. oosen the left two attachment bolts and support the shafts and their connectors from below. To get the guide shafts out of the counter bore, you can slightly tap the attachment bolts down.
  5. Remove the two clamping bolts completely (on one side) and remove the entire unit, including the two guide shafts and their cross connector.
    Please pay attention that the shafts don’t fall down.
  6. This operation has to be done on the opposite side as well (see steps 4 and 5) to remove the entire indexing plate.
  7. Please follow the steps in reverse order to reinstall the indexing plate.
  8. Test manually if the unit lifts and moves freely.
Make sure that the unit moves freely before operating pneumatically.
 

Lift Locate Replacement of indexing plate